- 24 10/100Base-TX with M12 connector.
- 4 1000Base-LX/LC with M15-LC connector, can be connected into two gigabit rings.
- Support DT-Ring protocol suite (recovery time<50ms), RSTP/STP(IEEE802.1w/d) redundant protocol.
- Support ring, chain, star, and tangent ring network topologies.
- Advanced ring topology protocol avoiding broad-cast storm.
- Support IGMP Snooping, port mirroring, QoS, VLAN, ACL.
- Support multiple management functions including CLI, TELNET, WEB, SNMP V1/V2 and OPC etc.
- Support centralized management software, net-work topology generated automaticly.
- Safe MAC and port binding function, support static FDB.
- Bind width setting function enables port band width limitation.
- Improve network monitoring ability through RMON(group1,2,3,and 9)
- Broadcast storm control and unicast attack detection.
- EMC industrial level 4, specially designed for harsh electromagnetic interference environment.
- Abundant power supply options, able to provide redundant DC power supply.
- Support relay alarm output port alarming the lose of power.
- Unified management software for TOUGHCOM series: ToughComvision3.0.
- Working temperature: -40 ~ 85°C(-40 ~ 185°F).
- Ribbed Aluminum housing for heat dissipation, fanless design.
- Rack-mounting (19 inch 3U) installation.
- IP43 protection class.
Technical Specifications
Standard:
- IEEE802.3, IEEE 802.3u, IEEE 802.3x, IEEE802.3z, IEEE802.1d, IEEE802.1w, IEEE802.1p, IEEE802.1q, Store and forward switching mode
Interface:
- Gigabit port: Up to 4 x 1000Base-LX/LH with M15-LC connector
- Electrical ports: Up to 24 10/100Base-TX with M12 connector
- Console: RS232, RJ45
Performance:
- MAC Address Table Size: 8K
- Backplane switching capacity: 12.8G
Power Requirements:
- Power input: 24VDC (18-36VDC), 48VDC(36-72VDC), 110VDC(82-185VDC), 220VAC/DC(85-264VAC/120-370VDC)
- Input interface: M12
- Power consumption: <20W
Physical Characteristics:
- Casing: IP43 protection
- Ribbed Aluminum housing fanless design
- Dimensions(WxHxD): 482.6x132.5x245mm (19x5.22x9.65 in.)
- Weight: 6000g (13.228 pounds)
- Installation: Rack mounted 19 inch 3U
Environmental Limits:
- Operating Temperature: -40 ~ 85°C(-40 ~ 185°F)
- Storage Temperature: -40 ~ 85°C (-40 ~ 185°F)
- Humidity: 0 ~ 95% (no condensing)
Warranty:
Approvals:
- IEC61000-4-2(ESD): ±8KV contact discharge, ±15KV air discharge
- IEC61000-4-2(ESD): ±8KV contact discharge, ±15KV air discharge
- IEC61000-4-3(RS): 10V/M (80-1000MHz)
- IEC61000-4-4(EFT): power line±4KV, data line±2KV
- IEC61000-4-5(Surge): power line ±4KV CM/±2KV DM, data line±2KV
- IEC61000-4-6(CS): 3V(10KHZ-150KHZ),10V(150KHz-80MHz)
- IEC61000-4-8(Power frequency magnetic field): 100A/m cont. 1000A/m, 1s to 3s
- IEC61000-4-12/18(Damped oscillatory wave): 2.5KV CM, 1KV DM
- IEC61000-4-10(Damped oscillatory): 30A/m
- IEC61000-4-16(Common mode conduct): 30V cont. 300V, 1s
- FCC CFR47 Part 15/EN55022: Class A&B
- CE, FCC, ROHS
Ordering Information
|